Results
FIELD TRIAL & ENDURANCE TEST
- 760 frac stages and passed high/low pressure testing when returned to facility
- 3 input zipper valves on a 3 well zipper manifold that was moved 3 consecutive times on same pad
- 300 millions pounds of 100/300 mesh sand pumped
- Over 19,000 endurance cycles at 15,000 psi full differential
- Performed on 7”-15K Magnum SP valve in R&D lab
- Field trials started May 2021
- No internal valve failures and no grease pumped during onsite operations