FIELD TRIAL & ENDURANCE TEST

  • 760 frac stages and passed high/low pressure testing when returned to facility
    • 3 input zipper valves on a 3 well zipper manifold that was moved 3 consecutive times on same pad
    • 300 millions pounds of 100/300 mesh sand pumped
  • Over 19,000 endurance cycles at 15,000 psi full differential
    • Performed on 7”-15K Magnum SP valve in R&D lab
  • Field trials started May 2021

  • No internal valve failures and no grease pumped during onsite operations